Type A: Standard FIBC
Constructed from plain polypropylene or other non-conductive materials. Type A bags offer no static protection
whatsoever. As product moves over the inner surface during filling or discharging, a significant electrostatic charge can
accumulate.
Risk: High probability of propagating brush discharges.
Safe Use: Transporting non-flammable products in environments completely free of flammable solvents or combustible dusts.
Type B: Low Breakdown Voltage
Similar to Type A in construction, but manufactured using materials with a low breakdown voltage (typically less than 6 kV). This specific material property prevents the occurrence of highly energetic propagating brush discharges, though normal brush discharges can still occur.
"While Type B prevents massive propagating discharges, it does not dissipate static charge. Therefore, it is still unsafe for environments with flammable vapors."
Type C: Conductive (Groundable)
Also known as "groundable" FIBCs. Type C bags are woven with a grid of interwoven conductive threads. These
threads must be electrically connected to each other and, crucially, must be physically grounded during both filling
and discharging operations.
MECHANISM
Safely conducts static charge directly to the ground via the conductive grid.
CRITICAL WARNING
If ungrounded, Type C bags become highly dangerous, acting as a massive capacitor capable of generating severe sparks.
Type D: Static Dissipative
Constructed from specialised static-dissipative fabrics that safely dissipate static charge into the atmosphere via safe,
low-energy corona discharges. The advantage of Type D is that it does not require grounding.
The trade-off is that the fabric can lose its properties if contaminated with water or grease, so it is specified against the
working environment as well as the material.
Ideal for hazardous environments where grounding might be forgotten or compromised by human error.
Safe for combustible dusts and flammable solvents.
Type D: Static Dissipative
| FIBC TYPE | Grounding required | SPECIFICATION | Safe use |
|---|---|---|---|
| Type A | None | N/A | Non-hazardous only. No flammable gases/dusts. |
| Type B | Low breakdown voltage (<6kV) | No | Dry combustible dusts (MIE > 3mJ). No flammable gases. |
| Type C | Conductive Grid | Yes | Flammable gases, vapors, and combustible dusts (if grounded). |
| Type D | Static Dissipative (Corona discharge) | No | Flammable gases, vapors, and combustible dusts. |